Filtreler
Filtreler
Bulunan: 15 Adet 0.002 sn
Ambargo Durumu [1]
Tam Metin [1]
Veritabanı [1]
Tür [1]
Yayın Tarihi [1]
Dergi Sayısı [6]
Yayın Dili [2]
FAKÜLTELERİzmir Katip Çelebi Üniversitesi Kurum Koleksiyonu
FAKÜLTELERİzmir Katip Çelebi Üniversitesi Kurum Koleksiyonu
Erişime Açık

Evaluation of root resorption following rapid maxillary expansion using cone-beam computed tomography

ASLI BAYSAL | MEHMET İRFAN KARADEDE | İLKNUR VELİ

Objective: To evaluate the root resorption after rapid maxillary expansion (RME) via cone-beam computed tomography (CBCT). Materials and Methods: Records of 25 patients who had undergone RME with tooth-borne banded expander were obtained from the archive of the orthodontic department. CBCT data were reconstructed with surface and volume rendering, and the volumetric images were manipulated to display the root surfaces from various orientations. On these three-dimensional images, permanent first molars and first and second premolars were segmented, and their roots were isolated. Volumes ...Daha fazlası

Erişime Açık

Açık apeksli dişlerde MTA fillapex'in apikal sızıntıya etkisinin değerlendirilmesi

MERVE AKÇAY

Amaç: Nekrotik pulpalı immatür dişlerde kök ucunun açık olması, kök kanal sisteminin geniş ve kök ucuna doğru genişleyerek sonlanması nedeniyle bu dişlerde endodontik tedavi ile etkili bir apikal tıkama oluşturulması oldukça zordur. Bu yüzden bu dişlerin endodontik tedavilerinde kullanılacak kök kanal dolgu sisteminin apikal tıkama özelliği önem kazanmaktadır. Çalışmamızda hazırlanan simule immatür dişlerde yeni üretilmiş MTA Fillapex kanal dolgu patının Güta-perka ile birlikte kullanımı ve oluşturduğu apikal tıkamanın etkinliği Güta-perka/AH Plus kanal dolgu sistemi ile karşılaştırılarak in v ...Daha fazlası

Erişime Açık

Comparison of three different orthodontic wires for bonded lingual retainer fabrication

ASLI BAYSAL |

Objective We evaluated the detachment force, amount of deformation, fracture mode, and pull-out force of 3 different wires used for bonded lingual retainer fabrication. Methods We tested 0.0215-inch five-stranded wire (PentaOne, Masel; group I), 0.016 × 0.022-inch dead-soft eight-braided wire (Bond-A-Braid, Reliance; group II), and 0.0195-inch dead-soft coaxial wire (Respond, Ormco; group III). To test detachment force, deformation, and fracture mode, we embedded 94 lower incisor teeth in acrylic blocks in pairs. Retainer wires were bonded to the teeth and vertically directed force was ap ...Daha fazlası

6698 sayılı Kişisel Verilerin Korunması Kanunu kapsamında yükümlülüklerimiz ve çerez politikamız hakkında bilgi sahibi olmak için alttaki bağlantıyı kullanabilirsiniz.

creativecommons
Bu site altında yer alan tüm kaynaklar Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.
Platforms