Introduction: The aim of this study was to evaluate the prevalence of bacteremia associated with an orthodontic
stripping procedure. Methods: The study included 29 orthodontic patients (mean age, 18.2 6 3.4 years). We
used a standardized stripping procedure: a perforated stripping disk with a contra-angle hand piece was used
at a low speed (\15,000 rpm; 10 seconds) on the mandibular anterior teeth. Blood samples were collected
by inserting a cannula into the left antecubital fossa. A baseline sample was taken before treatment, and
a second sample was taken after the stripping procedure. T ...Daha fazlası
Introduction: The aims of this study were to evaluate the effect of an antibacterial monomer-containing selfetching
adhesive in reducing enamel demineralization around orthodontic brackets in vivo and to compare it
with the conventional adhesive system quantitatively. Methods: Fourteen orthodontic patients were randomly
divided into 2 equal groups; they received brackets fitted to all their teeth, bonded with either Clearfil Protect
Bond (Kuraray Medical, Okayama, Japan) (experimental group) or Transbond XT (3M Unitek, Monrovia, Calif)
(control group). Block randomization to obtain equal ...Daha fazlası
Introduction: The aim of this prospective clinical trial was to assess the effects of varying force directions on the
dynamic measurement of natural head position and orofacial airway dimensions of Class III patients during maxillary
orthopedic protraction compared with an untreated control group. Methods: The conventional facemask
group comprised 15 patients (8 girls, 7 boys; mean age, 9.6 6 1.3 years), the modified facemask group comprised
15 patients (7 girls, 8 boys; mean age, 9.5 6 1.5 years), and the control group comprised 15 subjects
(7 girls, 8 boys; mean age, 9.8 6 1.6 years). N ...Daha fazlası
Introduction: The aim of this study was to determine the peri-miniscrew implant crevicular fluid receptor
activator of nuclear factor-lB ligand (RANKL) and osteoprotegerin (OPG) levels around loaded and unloaded
miniscrew implants at different time intervals. Methods: Twenty loaded and 16 unloaded miniscrew implants
were included in this study. All miniscrew implants were placed bilaterally between the maxillary second premolars
and first molars as anchorage units for canine distalization. Peri-miniscrew implant crevicular fluid was taken
from the mesiobuccal aspects of the loaded and unl ...Daha fazlası
6698 sayılı Kişisel Verilerin Korunması Kanunu kapsamında yükümlülüklerimiz ve çerez politikamız hakkında bilgi sahibi olmak için alttaki bağlantıyı kullanabilirsiniz.