Objective: In this study investigates the effect of the type and volume of solution used in inflation of the foley catheter balloon on the development of urine leakage around the catheter during indwelling urethral catheterization. Material and Method: This randomized controlled experimental study was conducted with 128 patients hospitalized in the intensive care unit and carried out between 2015 and 2019. In each study group, different types and volumes of the solution including 10 mL 0.9% sodium chloride, 15 mL 0.9% sodium chloride, 10 mL sterile distilled water, and 15 mL sterile distilled water were used to inflate the foley balloon. Results: In the study, 7% of the patients who underwent indwelling urinary catheterization had urine leakage around the catheter. Urine leakage occurred on a mean of 11.33±8.22 days of catheterization. The urine leakage rate was calculated as 7.22/1000 catheterization days. Urine leakage rates of 10 mL 0.9% sodium chloride, 15 mL 0.9% sodium chloride, 10 mL sterile distilled water, and 15 mL sterile distilled water on the day of 1000 catheterization were 7.72, 5.60, 13.25, and 3.01 catheterization days, respectively. The most frequent urine leakage was in catheterizations using 10 mL sterile distilled water. Urine leakage was lower in catheterizations using 15 mL sterile distilled water compared to other groups. Conclusion: Using 15 mL of sterile distilled water to inflate the balloon can minimize urine leakage to ensure that the catheterization continues safely
Amaç: Bu çalışma foley kateter balonunun şişirilmesinde kullanılan solüsyon tipi ve hacminin kalıcı üretral kataterizasyon sırasında kateter etrafından idrar sızıntısı gelişimi üzerindeki etkisini incelemektedir. Foley balonun şişirilmesi için her bir çalışma grubunda 10 mL %0,9 sodyum klorür, 15 mL %0,9 sodyum klorür, 10 mL steril distile su ve 15 mL steril distile su olmak üzere farklı tip ve hacimLerde solüsyon kullanıldı. Gereç ve Yöntem: Bu randomize kontrollü deneysel çalışma, yoğun bakım ünitesinde yatan 128 hasta ile 2015-2019 yılları arasında yürütüldü. Bulgular: Çalışmada kalıcı üriner kateterizasyon uygulanan hastaların %7'sinde kateter çevresinde idrar sızıntısı gelişti. Kateterizasyonun ortalama 11,33±8,22 gününde idrar sızıntı meydana geldi. 1000 kateterizasyon gününde 10 mL %0.9 sodyum klorür, 15 mL %0,9 sodyum klorür, 10 mL steril distile su ve 15 mL steril distile su için idrar sızıntısı oranları sırasıyla 7,72, 5,60, 13,25 ve 3,01 gündü. En sık idrar sızıntı 10 mL steril distile suyun kullanıldığı kateterizasyonlarda gelişti. 15 mL steril distile su kullanılan kateterizasyonlarda idrar sızıntısı oranı diğer gruplara göre daha düşüktü. Sonuç: Balonu şişirmek için 15 mL steril distile su kullanmak, kateterizasyonun güvenli bir şekilde devam etmesini sağlamak için idrar sızıntısını en aza indirebilir.
Eser Adı (dc.title) | Investigation of Optimal Solution Type and Volume for Inflation of Foley Catheter Balloon in Indwelling Urethral Catheterization |
Eser Sahibi (dc.contributor.author) | AYŞE AKBIYIK |
Yayın Tarihi (dc.date.issued) | 2022 |
Diğer Yazarlar (dc.contributor.authors) | Ebru ÖZEL |
Diğer Yazarlar (dc.contributor.authors) | Perihan ÇETİN |
Diğer Yazarlar (dc.contributor.authors) | Leyla KHORSHID |
Yayıncı (dc.publisher) | İzmir Kâtip Çelebi Üniversitesi Sağlık Bilimleri Fakültesi |
Tür (dc.type) | Makale |
Özet (dc.description.abstract) | Objective: In this study investigates the effect of the type and volume of solution used in inflation of the foley catheter balloon on the development of urine leakage around the catheter during indwelling urethral catheterization. Material and Method: This randomized controlled experimental study was conducted with 128 patients hospitalized in the intensive care unit and carried out between 2015 and 2019. In each study group, different types and volumes of the solution including 10 mL 0.9% sodium chloride, 15 mL 0.9% sodium chloride, 10 mL sterile distilled water, and 15 mL sterile distilled water were used to inflate the foley balloon. Results: In the study, 7% of the patients who underwent indwelling urinary catheterization had urine leakage around the catheter. Urine leakage occurred on a mean of 11.33±8.22 days of catheterization. The urine leakage rate was calculated as 7.22/1000 catheterization days. Urine leakage rates of 10 mL 0.9% sodium chloride, 15 mL 0.9% sodium chloride, 10 mL sterile distilled water, and 15 mL sterile distilled water on the day of 1000 catheterization were 7.72, 5.60, 13.25, and 3.01 catheterization days, respectively. The most frequent urine leakage was in catheterizations using 10 mL sterile distilled water. Urine leakage was lower in catheterizations using 15 mL sterile distilled water compared to other groups. Conclusion: Using 15 mL of sterile distilled water to inflate the balloon can minimize urine leakage to ensure that the catheterization continues safely |
Özet (dc.description.abstract) | Amaç: Bu çalışma foley kateter balonunun şişirilmesinde kullanılan solüsyon tipi ve hacminin kalıcı üretral kataterizasyon sırasında kateter etrafından idrar sızıntısı gelişimi üzerindeki etkisini incelemektedir. Foley balonun şişirilmesi için her bir çalışma grubunda 10 mL %0,9 sodyum klorür, 15 mL %0,9 sodyum klorür, 10 mL steril distile su ve 15 mL steril distile su olmak üzere farklı tip ve hacimLerde solüsyon kullanıldı. Gereç ve Yöntem: Bu randomize kontrollü deneysel çalışma, yoğun bakım ünitesinde yatan 128 hasta ile 2015-2019 yılları arasında yürütüldü. Bulgular: Çalışmada kalıcı üriner kateterizasyon uygulanan hastaların %7'sinde kateter çevresinde idrar sızıntısı gelişti. Kateterizasyonun ortalama 11,33±8,22 gününde idrar sızıntı meydana geldi. 1000 kateterizasyon gününde 10 mL %0.9 sodyum klorür, 15 mL %0,9 sodyum klorür, 10 mL steril distile su ve 15 mL steril distile su için idrar sızıntısı oranları sırasıyla 7,72, 5,60, 13,25 ve 3,01 gündü. En sık idrar sızıntı 10 mL steril distile suyun kullanıldığı kateterizasyonlarda gelişti. 15 mL steril distile su kullanılan kateterizasyonlarda idrar sızıntısı oranı diğer gruplara göre daha düşüktü. Sonuç: Balonu şişirmek için 15 mL steril distile su kullanmak, kateterizasyonun güvenli bir şekilde devam etmesini sağlamak için idrar sızıntısını en aza indirebilir. |
Kayıt Giriş Tarihi (dc.date.accessioned) | 08.07.2022 |
Açık Erişim Tarihi (dc.date.available) | 2022-07-08 |
Yayın Dili (dc.language.iso) | eng |
Konu Başlıkları (dc.subject) | Indwelling urethral catheter |
Konu Başlıkları (dc.subject) | Saline |
Konu Başlıkları (dc.subject) | Balloon |
Konu Başlıkları (dc.subject) | Urine leakage |
Konu Başlıkları (dc.subject) | Sterile distilled water |
Konu Başlıkları (dc.subject) | Kalıcı üretral kateter |
Konu Başlıkları (dc.subject) | Salin |
Konu Başlıkları (dc.subject) | İdrar kaçağı |
Konu Başlıkları (dc.subject) | Steril distile su |
Konu Başlıkları (dc.subject) | Balon |
Atıf için Künye (dc.identifier.citation) | Akbıyık, A. , Özel, E. , Çetin, P. & Khorshid, L. (2022). Investigation of Optimal Solution Type and Volume for Inflation of Foley Catheter Balloon in Indwelling Urethral Catheterization . İzmir Katip Çelebi Üniversitesi Sağlık Bilimleri Fakültesi Dergisi , 7 (2) , 289-293 . Retrieved from https://dergipark.org.tr/tr/pub/ikcusbfd/issue/70141/957995 |
Alternatif Yayın Başlığı (dc.title.alternative) | Kalıcı Üretral Kateterizasyonda Foley Kateter Balonunun Şişirilmesi İçin Optimal Solüsyon Tipi ve Hacminin İncelenmesi |
ISSN (dc.identifier.issn) | 2458-9799 |
Yayının ilk sayfa sayısı (dc.identifier.startpage) | 289 |
Yayının son sayfa sayısı (dc.identifier.endpage) | 293 |
Dergi Adı (dc.relation.journal) | İzmir Kâtip Çelebi Üniversitesi Sağlık Bilimleri Fakültesi Dergisi |
Dergi Sayısı (dc.identifier.issue) | 2 |
Dergi Cilt (dc.identifier.volume) | 7 |
Haklar (dc.rights) | Open access |
Tek Biçim Adres (dc.identifier.uri) | https://hdl.handle.net/11469/2083 |