Filtreler
Filtreler
Bulunan: 41 Adet 0.001 sn
Tam Metin [1]
Yayın Dili [2]
Effects of demineralizaton-inhibition procedures on the bond strength of brackets bonded to demineralized enamel surface

TANCAN UYSAL

Makale | 2012 | The Korean Association of Orthodontists

Objective: To study and compare the effects of different demineralizationinhibition methods on the shear bond strength (SBS) and fracture mode of an adhesive used to bond orthodontic brackets to demineralized enamel surfaces. Methods: Eighty freshly extracted, human maxillary premolars were divided into 4 equal groups and demineralized over the course of 21 days. Brackets were bonded to the demineralized enamel of teeth in Group 1. In Group 2, bonding was performed following resin infi ltration (ICON®, DMG, Hamburg, Germany). Before bonding, pre-treatment with acidulated phosphate fluoride (APF) or solutions containing casei . . .n phosphopeptide-amorphous calcium phosphate with 2% neutral sodium fluoride (CPP-ACP/wF) was performed in Groups 3 and 4, respectively. Th e SBS values of the brackets were measured and recorded following mechanical shearing of the bracket from the tooth surface. Th e adhesive remnant index (ARI) scores were determined aft er the brackets failed. Statistical comparisons were performed using one-way ANOVA, Tukey’s post-tests, and G-tests. Results: Significant differences were found in some of the intergroup comparisons of the SBS values (F = 39.287, p < 0.001). No signifi cant diff erences were found between the values for the APF-gel and control groups, whereas signifi cantly higher SBS values were recorded for the resin-infi ltrated and CPPACP/ wF-treated groups. Th e ARI scores were also signifi cantly diff erent among the 4 groups (p < 0.001). Conclusions: Tooth surfaces exposed to resin infi ltration and CPP-ACP/wF application showed higher debonding forces than the untreated, demineralized surfaces Daha fazlası Daha az

Farklı kanal dolgu patlarının koronal sızıntıya etkisinin karşılaştırmalı olarak değerlendirilmesi

MERVE AKÇAY

Makale | 2012 | Türkiye Klinikleri

Amaç: Koronal örtücülük, endodontik tedavinin başarısını ve periapikal doku sağlığını etkileyen kritik bir faktördür. Gereç ve Yöntemler: Çalışmamızda yeni üretilmiş MTA Fillapex kanal dolgu patının Güta-perka ile birlikte kullanımı ve oluşturduğu koronal tıkamanın etkinliği Güta-perka/AH Plus kanal dolgu sistemi ile karşılaştırılarak in vitro koşullarda değerlendirilmiştir. Çalışmada 20 adet örnek Güta-perka/MTA Fillapex, 20 adet örnek Güta-perka/AH Plus ile doldurulmuştur. Bulgular: Boya penetrasyon testi ile elde edilen sonuçlar istatistiksel olarak değerlendirildiğinde Güta-perka/MTA Fillapex ile Güta-perka/AH Plus sistemi arası . . .nda koronal örtücülük açısından anlamlı bir farklılık bulunmamıştır (p>0,05). Sonuç: Çalışma sonuçları değerlendirildiğinde MTA Fillapex materyalinin in vivo koşullardaki etkinliğini değerlendiren klinik çalışmaların yapılması gerekmektedir. Objective: Coronal sealing is a critical factor which effects the succes of endodontic treatment and periapical tissue health. Material and Methods: In the present study, comparative evaluation of a recently produced material, MTA Fillapex used with Gutta percha and AH-Plus used with Gutta-percha regarding their coronal sealing efficiency in in vitro conditions. 20 specimens were filled with Gutta-percha/MTA Fillapex and the other 20 specimens were filled with Gutta-percha/AH Plus root canal filling system. Results: Dye penetration test was used to compare two groups and according to the statistical analysis, there was no significant differences between Gutta-percha/MTA Fillapex and Gutta-percha/AH Plus (p>0.05). Conclusion: According to the results, further clinical studies evaluating MTA Fillapex root canal sealer's efficiency in in vivo conditions are necessary Daha fazlası Daha az

An In Vitro Comparison of Different Diagnostic Methods in Detection of Residual Dentinal Caries

EBRU KÜÇÜKYILMAZ

Makale | 2010 | Hindawi Publishing Corporation

The aim of this study was to investigate the efficiency of different diagnostic methods in detection of residual dentinal caries in excavated cavities. Fifty extracted molar with deep dentinal carious lesions were excavated using a slow-speed handpiece. All cavities were assessed by laser fluorescence(LF) device, electronic caries monitor(ECM), and caries detector dye(CDD) by three independent observers blindly. The measurements were repeated after two weeks. Specimens containing dentin slices 150 μm in thickness were prepared for histological analyses. The existence and absence of carious dentin was determined using a lig . . .htmicroscope. The average intraobserver accuracy was 1.00 (perfect agreement) for CDD, 0.86 (excellent agreement) for ECM, and 0.50 (good agreement) for LF. The average interobserver accuracy values were 0.92 (excellent agreement), (0.36 marginal agreement) and 0.48 (good agreement), for CDD, ECM, and LF, respectively. The average specificity was 0.60 for CDD, 73% for ECM, and 0.50 for LF. The average sensitivity was 0.55 for CDD, 0.85 for LF, and 0.47 for ECM. The average accuracy values were 0.53, 0.51, and 0.81 for CDD, ECM, and LF, respectively. LF had the greatest sensitivity and accuracy values of any of the methods tested. As a conclusion, LF device is appeared to most reliable method in detection of remain caries in cavity. However, because of its technical sensitivity it may susceptible to variations in measurements. To pay attention to the rule of usage and repeated measurements can minimize such variations in clinical practice. It was concluded that LF is an improvement on the currently available aids for residual caries detection Daha fazlası Daha az

MTA-fillapex'in radyoopasitesinin gri MTA ile karşılaştırmalı olarak değerlendirilmesi

MERVE AKÇAY

Makale | 2012 | Türkiye Klinikleri

Amaç: Bu çalışmada MTA-Fillapex'in radyoopasitesinin dijital görüntüleme tekniği kullanılarak, Gri MTA ile karşılaştırmalı değerlendirilmesi amaçlandı. Gereç ve Yöntemler: Çalışmada Gri MTA Angelus'un ve MTA-Fillapex'in (Angelus, Londrina, Brezilya) opazitesi değerlendirildi. Örneklerin yerleştirilmesi için 1 mm derinliğinde ve 5 mm çapında 5 akrilik levha hazırlandı. Akrilik levhalar üzerinde ayrıca alüminyumdan yapılmış penetremetre yerleştirilerek opasite yoğunluğu hesaplandı. Radyografik değerlendirme, direkt dijital görüntüleme tekniği ile yapıldı. Tüm radyograflar sıkıştırma algoritması olmaksızın TIFF formatında kaydedildi. D . . .aha sonra kaydedilen görüntüler üzerinde densite değerleri mm alüminyum (mmAl) eşdeğerinde belirlendi. Bu süreç her bir örnek için üç kez tekrarlandı ve ortalamaları hesaplandı. İstatistiksel değerlendirmeler Mann Whitney U testi ile yapıldı. Bulgular: MTA Angelus'un radyoopasite değerinin 6,48 mm Al, MTA Fillapex'in ise 1,8 mm Al olduğu belirlendi ve iki materyal arasında hesaplanan değerler arasında istatistiksel olarak anlamlı fark olduğu belirlendi ( Daha fazlası Daha az

6698 sayılı Kişisel Verilerin Korunması Kanunu kapsamında yükümlülüklerimiz ve çerez politikamız hakkında bilgi sahibi olmak için alttaki bağlantıyı kullanabilirsiniz.

creativecommons
Bu site altında yer alan tüm kaynaklar Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.
Platforms