Investigation of Optimal Solution Type and Volume for Inflation of Foley Catheter Balloon in Indwelling Urethral Catheterization

AYŞE AKBIYIK

Makale | 2022 | İzmir Kâtip Çelebi Üniversitesi Sağlık Bilimleri Fakültesi Dergisi 7 ( 2 ) , pp.289 - 293

Objective: In this study investigates the effect of the type and volume of solution used in inflation of the foley catheter balloon on the development of urine leakage around the catheter during indwelling urethral catheterization. Material and Method: This randomized controlled experimental study was conducted with 128 patients hospitalized in the intensive care unit and carried out between 2015 and 2019. In each study group, different types and volumes of the solution including 10 mL 0.9% sodium chloride, 15 mL 0.9% sodium chloride, 10 mL sterile distilled water, and 15 mL sterile distilled water were used to inflate the foley bal . . .loon. Results: In the study, 7% of the patients who underwent indwelling urinary catheterization had urine leakage around the catheter. Urine leakage occurred on a mean of 11.33±8.22 days of catheterization. The urine leakage rate was calculated as 7.22/1000 catheterization days. Urine leakage rates of 10 mL 0.9% sodium chloride, 15 mL 0.9% sodium chloride, 10 mL sterile distilled water, and 15 mL sterile distilled water on the day of 1000 catheterization were 7.72, 5.60, 13.25, and 3.01 catheterization days, respectively. The most frequent urine leakage was in catheterizations using 10 mL sterile distilled water. Urine leakage was lower in catheterizations using 15 mL sterile distilled water compared to other groups. Conclusion: Using 15 mL of sterile distilled water to inflate the balloon can minimize urine leakage to ensure that the catheterization continues safely Amaç: Bu çalışma foley kateter balonunun şişirilmesinde kullanılan solüsyon tipi ve hacminin kalıcı üretral kataterizasyon sırasında kateter etrafından idrar sızıntısı gelişimi üzerindeki etkisini incelemektedir. Foley balonun şişirilmesi için her bir çalışma grubunda 10 mL %0,9 sodyum klorür, 15 mL %0,9 sodyum klorür, 10 mL steril distile su ve 15 mL steril distile su olmak üzere farklı tip ve hacimLerde solüsyon kullanıldı. Gereç ve Yöntem: Bu randomize kontrollü deneysel çalışma, yoğun bakım ünitesinde yatan 128 hasta ile 2015-2019 yılları arasında yürütüldü. Bulgular: Çalışmada kalıcı üriner kateterizasyon uygulanan hastaların %7'sinde kateter çevresinde idrar sızıntısı gelişti. Kateterizasyonun ortalama 11,33±8,22 gününde idrar sızıntı meydana geldi. 1000 kateterizasyon gününde 10 mL %0.9 sodyum klorür, 15 mL %0,9 sodyum klorür, 10 mL steril distile su ve 15 mL steril distile su için idrar sızıntısı oranları sırasıyla 7,72, 5,60, 13,25 ve 3,01 gündü. En sık idrar sızıntı 10 mL steril distile suyun kullanıldığı kateterizasyonlarda gelişti. 15 mL steril distile su kullanılan kateterizasyonlarda idrar sızıntısı oranı diğer gruplara göre daha düşüktü. Sonuç: Balonu şişirmek için 15 mL steril distile su kullanmak, kateterizasyonun güvenli bir şekilde devam etmesini sağlamak için idrar sızıntısını en aza indirebilir Daha fazlası Daha az

Examining the Effect of Venipuncture Technique with Vacutainer and Injector on the Rate of Hemolysis

BURCU CEYLAN | SALİHA AKSUN | AYŞE AKBIYIK | DERYA UZELLİ YILMAZ | ESRA AKIN

Makale | 2022 | İzmir Kâtip Çelebi Üniversitesi Sağlık Bilimleri Fakültesi Dergisi 7 ( 2 ) , pp.307 - 312

Objective: This study was conducted to determine hemolysis rates for venous blood samples drawn by injector and vacutainer holder and to assess the effect of the venipuncture technique on the process of hemolysis. Material and Method: This cross-sectional and analytical study was conducted with 128 patients who were admitted to the Cardiology and Angio clinics of a university hospital and met the inclusion criteria. One group of patients who were to have routine biochemical tests underwent venipuncture with an injector, and another group with a vacutainer. Results: The serum hemolysis level is not significantly different by gender. . . .No significant correlation was found between blood serum hemolysis levels and age or Body Mass Index with blood drawn with an injector or with a vacutainer. While the serum hemolysis level was on average 0.11 g/dl in blood drawn with an injector, the level in blood drawn with a vacutainer was 0.06 g/dl; the difference was not statistically significant. Conclusion: This study revealed that there was no statistically significant difference between hemolysis rates in blood drawn with an injector or with a vacutainer. However, the hemolysis rates in blood drawn with an injector were almost twice the rates noted in blood drawn with a vacutainer, and this difference may be clinically significant. Amaç: Bu araştırma enjektör ve vacutainer kullanılarak alınan venöz kanlarda hemoliz oranını belirlemek ve kan alma tekniğinin hemoliz gelişimi üzerindeki etkisini değerlendirmek amacıyla yapılmıştır. Gereç ve Yöntem: Kesitsel ve analitik tipte olan bu araştırma, bir üniversite hastanesinin Kardiyoloji ve Anjiyo kliniklerine yatışı yapılan ve araştırmaya dahil edilme kriterlerine uyan 128 hasta ile yürütülmüştür. Rutin biyokimyasal tetkikleri istenilen bir grup hastadan enjektörle, diğer gruptaki hastalardan vacutainer ile kan alınmıştır. Bulgular: Serum hemoliz düzeyi cinsiyetler arasında anlamlı olarak farklı değildir. Enjektör ve vacutainer ile alınan kan örneklerindeki serum hemoliz düzeyleri ile yaş ve Beden Kütle İndeksi arasında anlamlı korelasyon saptanmamıştır. Serum hemoliz düzeyi enjektör ile alınan kanlarda ortalama 0.11 g/dl iken vacutainer ile alınan kanlarda ortalama 0.06 g/dl olup bu fark istatistiksel olarak anlamlı bulunmamıştır. Sonuç: Bu araştırmada enjektör ve vacutainer ile alınan kan örneklerindeki hemoliz oranları istatistiksel olarak anlamlı farklılık göstermemiştir. Ancak enjektörle alınan kanlarda ortalama hemoliz oranı vacutainer ile alınan kanlardan neredeyse iki kat fazladır, bu fark klinik açıdan anlamlı olabilmektedir Daha fazlası Daha az

6698 sayılı Kişisel Verilerin Korunması Kanunu kapsamında yükümlülüklerimiz ve çerez politikamız hakkında bilgi sahibi olmak için alttaki bağlantıyı kullanabilirsiniz.

creativecommons
Bu site altında yer alan tüm kaynaklar Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.
Platforms