Examining the Effect of Venipuncture Technique with Vacutainer and Injector on the Rate of Hemolysis

Objective: This study was conducted to determine hemolysis rates for venous blood samples drawn by injector and vacutainer holder and to assess the effect of the venipuncture technique on the process of hemolysis. Material and Method: This cross-sectional and analytical study was conducted with 128 patients who were admitted to the Cardiology and Angio clinics of a university hospital and met the inclusion criteria. One group of patients who were to have routine biochemical tests underwent venipuncture with an injector, and another group with a vacutainer. Results: The serum hemolysis level is not significantly different by gender. No significant correlation was found between blood serum hemolysis levels and age or Body Mass Index with blood drawn with an injector or with a vacutainer. While the serum hemolysis level was on average 0.11 g/dl in blood drawn with an injector, the level in blood drawn with a vacutainer was 0.06 g/dl; the difference was not statistically significant. Conclusion: This study revealed that there was no statistically significant difference between hemolysis rates in blood drawn with an injector or with a vacutainer. However, the hemolysis rates in blood drawn with an injector were almost twice the rates noted in blood drawn with a vacutainer, and this difference may be clinically significant.


Amaç: Bu araştırma enjektör ve vacutainer kullanılarak alınan venöz kanlarda hemoliz oranını belirlemek ve kan alma tekniğinin hemoliz gelişimi üzerindeki etkisini değerlendirmek amacıyla yapılmıştır. Gereç ve Yöntem: Kesitsel ve analitik tipte olan bu araştırma, bir üniversite hastanesinin Kardiyoloji ve Anjiyo kliniklerine yatışı yapılan ve araştırmaya dahil edilme kriterlerine uyan 128 hasta ile yürütülmüştür. Rutin biyokimyasal tetkikleri istenilen bir grup hastadan enjektörle, diğer gruptaki hastalardan vacutainer ile kan alınmıştır. Bulgular: Serum hemoliz düzeyi cinsiyetler arasında anlamlı olarak farklı değildir. Enjektör ve vacutainer ile alınan kan örneklerindeki serum hemoliz düzeyleri ile yaş ve Beden Kütle İndeksi arasında anlamlı korelasyon saptanmamıştır. Serum hemoliz düzeyi enjektör ile alınan kanlarda ortalama 0.11 g/dl iken vacutainer ile alınan kanlarda ortalama 0.06 g/dl olup bu fark istatistiksel olarak anlamlı bulunmamıştır. Sonuç: Bu araştırmada enjektör ve vacutainer ile alınan kan örneklerindeki hemoliz oranları istatistiksel olarak anlamlı farklılık göstermemiştir. Ancak enjektörle alınan kanlarda ortalama hemoliz oranı vacutainer ile alınan kanlardan neredeyse iki kat fazladır, bu fark klinik açıdan anlamlı olabilmektedir.

Görüntülenme
84
06.07.2022 tarihinden bu yana
İndirme
1
06.07.2022 tarihinden bu yana
Son Erişim Tarihi
09 Mart 2024 23:17
Google Kontrol
Tıklayınız
vacutainer hemoliz alınan hemolysis injector anlamlı kanlarda significant ortalama enjektör olarak difference arasında düzeyi between enjektörle örneklerindeki istatistiksel venipuncture patients statistically araştırma conducted hastanesinin üniversite istenilen tetkikleri biyokimyasal Anjiyo yürütülmüştür Kardiyoloji araştırmaya kliniklerine yatışı yapılan
Tam Metin
Tam Metin İndirmek için tıklayın Ön izleme
Detaylı Görünüm
Eser Adı
(dc.title)
Examining the Effect of Venipuncture Technique with Vacutainer and Injector on the Rate of Hemolysis
Eser Sahibi
(dc.contributor.author)
BURCU CEYLAN
Eser Sahibi
(dc.contributor.author)
SALİHA AKSUN
Eser Sahibi
(dc.contributor.author)
AYŞE AKBIYIK
Eser Sahibi
(dc.contributor.author)
DERYA UZELLİ YILMAZ
Eser Sahibi
(dc.contributor.author)
ESRA AKIN
Yayın Tarihi
(dc.date.issued)
2022
Diğer Yazarlar
(dc.contributor.authors)
AYŞE AKBIYIK
Yayıncı
(dc.publisher)
İzmir Kâtip Çelebi Üniversitesi Sağlık Bilimleri Fakültesi
Tür
(dc.type)
Makale
Özet
(dc.description.abstract)
Objective: This study was conducted to determine hemolysis rates for venous blood samples drawn by injector and vacutainer holder and to assess the effect of the venipuncture technique on the process of hemolysis. Material and Method: This cross-sectional and analytical study was conducted with 128 patients who were admitted to the Cardiology and Angio clinics of a university hospital and met the inclusion criteria. One group of patients who were to have routine biochemical tests underwent venipuncture with an injector, and another group with a vacutainer. Results: The serum hemolysis level is not significantly different by gender. No significant correlation was found between blood serum hemolysis levels and age or Body Mass Index with blood drawn with an injector or with a vacutainer. While the serum hemolysis level was on average 0.11 g/dl in blood drawn with an injector, the level in blood drawn with a vacutainer was 0.06 g/dl; the difference was not statistically significant. Conclusion: This study revealed that there was no statistically significant difference between hemolysis rates in blood drawn with an injector or with a vacutainer. However, the hemolysis rates in blood drawn with an injector were almost twice the rates noted in blood drawn with a vacutainer, and this difference may be clinically significant. Amaç: Bu araştırma enjektör ve vacutainer kullanılarak alınan venöz kanlarda hemoliz oranını belirlemek ve kan alma tekniğinin hemoliz gelişimi üzerindeki etkisini değerlendirmek amacıyla yapılmıştır. Gereç ve Yöntem: Kesitsel ve analitik tipte olan bu araştırma, bir üniversite hastanesinin Kardiyoloji ve Anjiyo kliniklerine yatışı yapılan ve araştırmaya dahil edilme kriterlerine uyan 128 hasta ile yürütülmüştür. Rutin biyokimyasal tetkikleri istenilen bir grup hastadan enjektörle, diğer gruptaki hastalardan vacutainer ile kan alınmıştır. Bulgular: Serum hemoliz düzeyi cinsiyetler arasında anlamlı olarak farklı değildir. Enjektör ve vacutainer ile alınan kan örneklerindeki serum hemoliz düzeyleri ile yaş ve Beden Kütle İndeksi arasında anlamlı korelasyon saptanmamıştır. Serum hemoliz düzeyi enjektör ile alınan kanlarda ortalama 0.11 g/dl iken vacutainer ile alınan kanlarda ortalama 0.06 g/dl olup bu fark istatistiksel olarak anlamlı bulunmamıştır. Sonuç: Bu araştırmada enjektör ve vacutainer ile alınan kan örneklerindeki hemoliz oranları istatistiksel olarak anlamlı farklılık göstermemiştir. Ancak enjektörle alınan kanlarda ortalama hemoliz oranı vacutainer ile alınan kanlardan neredeyse iki kat fazladır, bu fark klinik açıdan anlamlı olabilmektedir.
Kayıt Giriş Tarihi
(dc.date.accessioned)
06.07.2022
Açık Erişim Tarihi
(dc.date.available)
2022-07-06
Yayın Dili
(dc.language.iso)
eng
Konu Başlıkları
(dc.subject)
Hemolysis
Konu Başlıkları
(dc.subject)
nursing practice
Konu Başlıkları
(dc.subject)
phlebotomy
Konu Başlıkları
(dc.subject)
technique
Konu Başlıkları
(dc.subject)
venipuncture
Konu Başlıkları
(dc.subject)
Kan alma
Konu Başlıkları
(dc.subject)
teknik
Konu Başlıkları
(dc.subject)
hemoliz
Konu Başlıkları
(dc.subject)
hemşirelik uygulaması
Atıf için Künye
(dc.identifier.citation)
Ceylan, B. , Aksun, S. , Akbıyık, A. , Uzelli Yılmaz, D. & Akın Korhan, E. (2022). Examining the Effect of Venipuncture Technique with Vacutainer and Injector on the Rate of Hemolysis . İzmir Katip Çelebi Üniversitesi Sağlık Bilimleri Fakültesi Dergisi , 7 (2) , 307-312 . Retrieved from https://dergipark.org.tr/tr/pub/ikcusbfd/issue/70141/970945
Alternatif Yayın Başlığı
(dc.title.alternative)
Vacutainer ve Enjektör ile Kan Alma Tekniğinin Hemoliz Oranına Etkisinin İncelenmesi
ISSN
(dc.identifier.issn)
2458-9799
Yayının ilk sayfa sayısı
(dc.identifier.startpage)
307
Yayının son sayfa sayısı
(dc.identifier.endpage)
312
Dergi Adı
(dc.relation.journal)
İzmir Kâtip Çelebi Üniversitesi Sağlık Bilimleri Fakültesi Dergisi
Dergi Sayısı
(dc.identifier.issue)
2
Dergi Cilt
(dc.identifier.volume)
7
Haklar
(dc.rights)
Open Access
Tek Biçim Adres
(dc.identifier.uri)
https://hdl.handle.net/11469/2037
Analizler
Yayın Görüntülenme
Yayın Görüntülenme
Erişilen ülkeler
Erişilen şehirler
6698 sayılı Kişisel Verilerin Korunması Kanunu kapsamında yükümlülüklerimiz ve çerez politikamız hakkında bilgi sahibi olmak için alttaki bağlantıyı kullanabilirsiniz.

creativecommons
Bu site altında yer alan tüm kaynaklar Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.
Platforms