Measurements from conventional, digital and CT-derived cephalograms: a comparative study

ASLI BAYSAL

Makale | 2012 | Australian Society of Orthodontists

Objective: The purpose of this retrospective radiographic study was to determine the reliability and reproducibility of skeletal and dental measurements of lateral cephalograms created from a computerised tomography (CT) scan compared with conventional and digital lateral cephalograms. Methods: CT and conventional lateral cephalograms of the same patients were obtained from university archives. The lateral cephalometric radiographs of 30 patients were manually traced. The radiographs were subsequently scanned and traced using Dolphin Imaging software version 11 (Dolphin Imaging, Chatsworth, CA, USA). The CT-created lateral ceph . . .alograms were also traced using the same software. Sixteen (10 angular and 6 linear) measurements were performed. Cephalometric measurements obtained from conventional, digital and CT-created cephalograms were statistically compared using repeated measures analysis of variance (ANOVA). Statistical significance was set at the p < 0.05 level of confidence. Results: The intra-rater reliability test for each method showed high values (r > 0.90) except for mandibular length which had a correlation of 0.82 for the CT-created cephalogram. Five measurements (N-A-Pog, N-S, ANS-PNS, Co-ANS and Co-Gn) were found to be significantly different between the CT-created and conventional cephalograms and three measurements (SNB, ANB, and /1-MP) were found to be significantly different between the CT-created and digital cephalograms. Conclusions: There are statistically-significant differences in measurements produced using a traditional manual analysis, a direct digital analysis or a 3D CT-derived cephalometric analysis of orthodontic patients. These differences are, on average, small but because of individual variation, may be of considerable clinical significance in some patients Daha fazlası Daha az

Do enamel microabrasion and casein phosphopeptide-amorphous calcium phosphate affect shear bond strength of orthodontic brackets bonded to a demineralized enamel surface?

ASLI BAYSAL |

Makale | 2012 | The E. H. Angle Education and Research Foundation

Objective: To evaluate and compare the effects of enamel microabrasion, casein phosphopeptide-amorphous calcium phosphate (CPP-ACP), and their combination on the shear bond strength (SBS) of orthodontic brackets bonded to demineralized enamel surface. Materials and Methods: One hundred human first premolar teeth were randomly allocated to one of five groups. Group I was considered as the control of other groups. For the remaining groups, demineralization was performed via solutions. In group II, brackets were directly bonded to the demineralized enamel surface. CPP-ACP was applied in group III, microabrasion was performed in grou . . .p IV, and both microabrasion and CPP-ACP application were performed in group V. The specimens were tested for SBS. Bond failures were scored according to the Adhesive Remnant Index (ARI). Analysis of variance and Tukey tests were used to compare the SBS of the groups. ARI scores of the groups were evaluated with a G-test. The statistical significance was set at P Daha fazlası Daha az

Ethnic differences in the soft tissue profiles of Turkish and European–American young adults with normal occlusions and well-balanced faces

ASLI BAYSAL | TANCAN UYSAL

Makale | 2012 | Oxford University Press on behalf of the European Orthodontic Society

The aim of this study was to evaluate soft tissue differences between Turkish and North American adults by comparing two sample populations with ideal occlusion and well-balanced faces. Lateral cephalometric radiographs of 117 Anatolian Turkish adults (65 female and 52 male, mean age: 23.9 ± 2.8 years) were compared with a sample of 116 adults of European–American ancestry (64 female and 52 male, mean age: 25.0 ± 6.8 years). The cephalometric analyses of Holdaway, Epker, and Legan and Burstone were performed using Dolphin Image Software 9.0. Thirty-two measurements (27 linear and 5 angular) were analysed. For statistical evaluation, . . . independent samples t-tests were performed. Distinct differences were found between the two samples in facial convexity, upper lip position and length, lower lip position, chin prominence, and chin thickness. Vertical proportional findings were similar between groups. Ethnic differences were found between Turkish and North American adults in the soft tissue profile. It is appropriate to consider these differences during routine diagnosis and treatment planning of a Turkish patient or an American patient of European ancestry Daha fazlası Daha az

Comparison of three different orthodontic wires for bonded lingual retainer fabrication

ASLI BAYSAL |

Makale | 2012 | The Korean Association of Orthodontists

Objective We evaluated the detachment force, amount of deformation, fracture mode, and pull-out force of 3 different wires used for bonded lingual retainer fabrication. Methods We tested 0.0215-inch five-stranded wire (PentaOne, Masel; group I), 0.016 × 0.022-inch dead-soft eight-braided wire (Bond-A-Braid, Reliance; group II), and 0.0195-inch dead-soft coaxial wire (Respond, Ormco; group III). To test detachment force, deformation, and fracture mode, we embedded 94 lower incisor teeth in acrylic blocks in pairs. Retainer wires were bonded to the teeth and vertically directed force was applied to the wire. To test pull-out forc . . .e, wires were embedded in composite that was placed in a hole at the center of an acrylic block. Tensile force was applied along the long axis of the wire. Results Detachment force and mode of fracture were not different between groups. Deformation was significantly higher in groups II and III than in group I (p < 0.001). Mean pull-out force was significantly higher for group I compared to groups II and III (p < 0.001). Conclusions Detachment force and fracture mode were similar for all wires, but greater deformations were seen in dead-soft wires. Wire pull-out force was significantly higher for five-stranded coaxial wire than for the other wires tested. Five-stranded coaxial wires are suggested for use in bonded lingual retainers Daha fazlası Daha az

Evaluation of root resorption following rapid maxillary expansion using cone-beam computed tomography

ASLI BAYSAL | MEHMET İRFAN KARADEDE | İLKNUR VELİ

Makale | 2012 | The E. H. Angle Education and Research Foundation

Objective: To evaluate the root resorption after rapid maxillary expansion (RME) via cone-beam computed tomography (CBCT). Materials and Methods: Records of 25 patients who had undergone RME with tooth-borne banded expander were obtained from the archive of the orthodontic department. CBCT data were reconstructed with surface and volume rendering, and the volumetric images were manipulated to display the root surfaces from various orientations. On these three-dimensional images, permanent first molars and first and second premolars were segmented, and their roots were isolated. Volumes of roots were calculated. The difference . . . between pre-expansion and postexpansion root volumes was statistically evaluated with a paired-samples t-test. Also, the percentage of root volume loss was calculated for each root and statistically compared with each other with one-way analysis of variance at the P , .05 level. Results: The difference between the pre-expansion and postexpansion root volumes was statistically significant for all roots investigated. Maximum volume decrease was observed for the mesiobuccal root of first molar teeth (18.60 mm3). It was determined that the distobuccal root of first molar teeth was less affected from the expansion procedure (9.47 mm3). No statistically significant difference was found for the percentage of root volume loss. Conclusion: Following RME treatment, significant root volume loss was observed for all investigated posterior teeth. However, the percentage of volume loss was not statistically different among roots. (Angle Orthod. 2012;82:488–494. Daha fazlası Daha az