Filtreler
Erişime Açık

Effects of demineralizaton-inhibition procedures on the bond strength of brackets bonded to demineralized enamel surface

TANCAN UYSAL

Objective: To study and compare the effects of different demineralizationinhibition methods on the shear bond strength (SBS) and fracture mode of an adhesive used to bond orthodontic brackets to demineralized enamel surfaces. Methods: Eighty freshly extracted, human maxillary premolars were divided into 4 equal groups and demineralized over the course of 21 days. Brackets were bonded to the demineralized enamel of teeth in Group 1. In Group 2, bonding was performed following resin infi ltration (ICON®, DMG, Hamburg, Germany). Before bonding, pre-treatment with acidulated phosphate fluor ...Daha fazlası

Erişime Açık

Comparison of three different orthodontic wires for bonded lingual retainer fabrication

ASLI BAYSAL |

Objective We evaluated the detachment force, amount of deformation, fracture mode, and pull-out force of 3 different wires used for bonded lingual retainer fabrication. Methods We tested 0.0215-inch five-stranded wire (PentaOne, Masel; group I), 0.016 × 0.022-inch dead-soft eight-braided wire (Bond-A-Braid, Reliance; group II), and 0.0195-inch dead-soft coaxial wire (Respond, Ormco; group III). To test detachment force, deformation, and fracture mode, we embedded 94 lower incisor teeth in acrylic blocks in pairs. Retainer wires were bonded to the teeth and vertically directed force was ap ...Daha fazlası

Erişime Açık

Influence of Pre-Orthodontic Trainer treatment on the perioral and masticatory muscles in patients with Class II division 1 malocclusion

TANCAN UYSAL |

The aim of this follow-up study was to evaluate the effects of Pre-Orthodontic Trainer (POT) appliance on the anterior temporal, mental, orbicularis oris, and masseter muscles through electromyography (EMG) evaluations in subjects with Class II division 1 malocclusion and incompetent lips. Twenty patients (mean age: 9.8 ± 2.2 years) with a Class II division 1 malocclusion were treated with POT (Myofunctional Research Co., Queensland, Australia). A group of 15 subjects (mean age: 9.2 ± 0.9 years) with untreated Class II division 1 malocclusions was used as a control. EMG recordings of treatment ...Daha fazlası

Erişime Açık

Resonance frequency analysis of orthodontic miniscrews subjected to light-emitting diode photobiomodulation therapy

TANCAN UYSAL

The aim of this prospective experimental study was to evaluate the effect of light-emitting diode (LED) photobiomodulation therapy (LPT) on the stability of immediately loaded miniscrews under different force levels, as assessed by resonance frequency analysis (RFA). Sixty titanium orthodontic miniscrews with a length of 8 mm and a diameter of 1.4 mm were implanted into cortical bone by closed flap technique in each proximal tibia of 15 New Zealand white adult male rabbits (n = 30). The animals were randomly divided into irradiated and control groups under different force levels (0, 150, and 3 ...Daha fazlası

6698 sayılı Kişisel Verilerin Korunması Kanunu kapsamında yükümlülüklerimiz ve çerez politikamız hakkında bilgi sahibi olmak için alttaki bağlantıyı kullanabilirsiniz.

creativecommons
Bu site altında yer alan tüm kaynaklar Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.
Platforms