Filtreler
Filtreler
Bulunan: 39 Adet 0.002 sn
Ambargo Durumu [1]
Tam Metin [1]
Tür [1]
Yayın Dili [2]
Erişime Açık

Rapid maxillary expansion effects on dynamic measurement of natural head position

TANCAN UYSAL

Objective: To identify the effect of rapid maxillary expansion (RME) procedure on dynamic measurement of natural head position (NHP). Materials and Methods: The treatment group comprised 23 patients, 12 girls and 11 boys (mean age: 10.1 6 1.1 years), and the control group comprised 15 subjects, 8 girls and 7 boys (mean age: 9.7 6 1.4 years). The test subjects underwent RME treatment using full cap acrylic device, and the mean amount of expansion was 5.48 mm. An inclinometer and a portable data logger were used to collect the NHP data. Intragroup changes were evaluated by using nonparamet ...Daha fazlası

Erişime Açık

Açık apeksli dişlerde MTA fillapex'in apikal sızıntıya etkisinin değerlendirilmesi

MERVE AKÇAY

Amaç: Nekrotik pulpalı immatür dişlerde kök ucunun açık olması, kök kanal sisteminin geniş ve kök ucuna doğru genişleyerek sonlanması nedeniyle bu dişlerde endodontik tedavi ile etkili bir apikal tıkama oluşturulması oldukça zordur. Bu yüzden bu dişlerin endodontik tedavilerinde kullanılacak kök kanal dolgu sisteminin apikal tıkama özelliği önem kazanmaktadır. Çalışmamızda hazırlanan simule immatür dişlerde yeni üretilmiş MTA Fillapex kanal dolgu patının Güta-perka ile birlikte kullanımı ve oluşturduğu apikal tıkamanın etkinliği Güta-perka/AH Plus kanal dolgu sistemi ile karşılaştırılarak in v ...Daha fazlası

Erişime Açık

Comparison of three different orthodontic wires for bonded lingual retainer fabrication

ASLI BAYSAL |

Objective We evaluated the detachment force, amount of deformation, fracture mode, and pull-out force of 3 different wires used for bonded lingual retainer fabrication. Methods We tested 0.0215-inch five-stranded wire (PentaOne, Masel; group I), 0.016 × 0.022-inch dead-soft eight-braided wire (Bond-A-Braid, Reliance; group II), and 0.0195-inch dead-soft coaxial wire (Respond, Ormco; group III). To test detachment force, deformation, and fracture mode, we embedded 94 lower incisor teeth in acrylic blocks in pairs. Retainer wires were bonded to the teeth and vertically directed force was ap ...Daha fazlası

6698 sayılı Kişisel Verilerin Korunması Kanunu kapsamında yükümlülüklerimiz ve çerez politikamız hakkında bilgi sahibi olmak için alttaki bağlantıyı kullanabilirsiniz.

creativecommons
Bu site altında yer alan tüm kaynaklar Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.
Platforms