Filtreler
Erişime Açık

A new web-based education and monitoring system for patients with type-2 diabetes mellitus Tip-2 diyabet hastaları için web tabanlı yeni bir eğitim ve izleme sistemi

Özçiftci, Hafsa Elif

ABSTRACTDiabetes Mellitus (DM) is a chronic disease that progresses rapidly. Today, thenumber of diabetic patients is increasing day by day, but treatment methods arebeginning to be inadequate due to the insufficient time, financial deficiencies andother restrictions. Diabetes education and treatment are very important for thediabetic to survive. Diabetes treatment is practiced in many areas of life from thenutrition habits to the social life activities. In terms of the course of diabetestreatment, it is necessary for the self-management of the patient to follow thediabetes education and appli ...Daha fazlası

Erişime Açık

EOG kontrollü çok yönlü tekerlekli sandalye

Afandi, Jamala

ÖZETBu tezde, EOG sinyalleri kullanılarak hareket yeteneği kısıtlı engelli bireyler için gerçek zamanlı çalışmalara uygulanması kolay bir tekerlekli sandalye kontrol algoritması geliştirilmiştir.Bu çalışmada, yaşları 20-26 arasında değişen 26 bireyden EOG sinyalleri alınmıştır. EOG sinyalleri olarak yatay EOG, sağ göz düşey EOG ve sol göz düşey EOG sinyalleri kayıt edilmiştir. Daha sonra her bir EOG kanalı 150 ms’lik medyan süzgecine tabi tutulmuştur. Böylece istemsiz yapılan göz kırpmaları ve çeşitli diğer gürültüler sinyalden arındırılabilmiştir. Geliştirilen algoritmaların girişine, her den ...Daha fazlası

Erişime Açık

Design of arduino shield to record real-time electrocardiography signals Elektrokardiyografi sinyallerinin gerçek zamanlı kaydı için elektronik filtreli ardunio eklentisi tasarımı

Çağatay, Onur Doğanay

ABSTRACTIn this thesis, an Arduino extension board (shield) is designed to take theelectrocardiography (ECG) signals. Firstly, the positive and negative terminals of an ECG signal are selected to determine which input pins are connected to these terminals. User can select one of eight possible inputs for each terminal, which means the user can apply one of the possible 64 channel combinations to inputs of the design. Then a dedicated instrumental amplifier amplifies the signal. The voltagegain of the amplifier can be selectable among available options. The amplified ECG signal is filtered in a ...Daha fazlası

6698 sayılı Kişisel Verilerin Korunması Kanunu kapsamında yükümlülüklerimiz ve çerez politikamız hakkında bilgi sahibi olmak için alttaki bağlantıyı kullanabilirsiniz.

creativecommons
Bu site altında yer alan tüm kaynaklar Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.
Platforms